Multifunction controllers

rosenthal design 
DeltaSol<sup>®</sup> MX Plus Multifunction controller

DeltaSol® MX Plus Multifunction controller

The DeltaSol® MX Plus combines the functional range of the DeltaSol® MX with an integrated Web server. Configuration, function control and access to VBus.net can be carried out easily and conveniently on any mobile device via a Web interface. Interfaces such as LAN and Modbus RTU (optional) as well as WLAN functionality and a WLAN access point offer many connectivity options.


Multifunction controller for solar and heating systems, incl. SD card
Article no.115 993 03 | Price bracket  A | Price on request
  Add to wish list
  • 15 relay outputs and 15 inputs for Pt1000, Pt500 or KTY temperature sensors
  • Up to 5 extension modules via VBus® (56 sensors and 40 relays in total)
  • Inputs for analogue and digital Grundfos Direct Sensors™ as well as for FRH and FRHd humidity sensors
  • Integrated control of up to 4 high-efficiency pumps via PWM. outputs
  • Cooling over the heating circuit with condensation detection
  • Dew point calculation by means of the FRH(d) humidity sensor to avoid condensation
  • Remote access to the heating circuits via the Web interface or room control unit(s)
  • Integrated Web server for configuration and function control
  • LAN interface, WLAN functionality, WLAN access point and optional Modbus RTU interface
  • Easy access to VBus.net via the Web interface
  • Operation via any mobile device
  • Heat pump demand (optional)
    Comparison DeltaSol® MX DeltaSol® MX Plus
    Inputs
    Temperature sensor inputs 12 15
    Impulse inputs 3 4
    Frequency inputs 1 2
    CS10 irradiation sensors 1 1
    Analogue inputs for VFS/RPS Grundfos Direct Sensors™ or FRH humidity sensors 2 2
    Digital inputs for VFD/RPD Grundfos Direct Sensors™ or FRHd humidity sensors 2 2
    Input for central outdoor sensor unit - 1
    Outputs
    Semiconductor relays 13 13
    Potential-free relay 1 1
    Potential-free low voltage relay - 1
    PWM outputs (convertible to 0-10 V signal outputs) 4 4
    Interfaces
    VBus®
    SD card slot
    LAN -*
    WLAN -*
    Modbus/RTU -
    Communication protocols
    Modbus/RTU -
    Modbus/TCP -*
    BACnet/IP -*
    Functions/Features (examples)
    Extended optional functions, e.g. solid fuel boiler function with mixer and target temperature control
    Cooling over the heating circuit with condensation detection
    Dew point calculation by means of the FRH(d) humidity sensor to avoid condensation
    Remote access to the heating circuits with room control unit(s) or the VBus®Touch HC App
    Heat pump demand (optional)
    Web interface -*
    Single-value parameterisation via web interface -

    * in conjunction with a DL2 Plus Datalogger
Max. number of collector fields:
31
Max. number of stores:
51
Weather-compensated heating circuits:
2 (72)
External heat exchanger:
check
Speed control of standard pumps:
check
Speed control of HE pumps:
check
■ via integrated PWM output:
check
■ via PSW adapter:
check
Temperature sensor inputs:
15
Sensor type:
Pt1000, Pt500, KTY
Inputs for Grundfos Direct Sensors™:
analog, digital
Input for CS10 irradiation sensor:
check
Impulse inputs for V40 flowmeter:
3
Relay outputs in total:
14
■ semiconductor relays (speed control):
13 (13)
■ electromechanical relay:
-
■ potential-free relay with changeover contact:
1
■ potential-free relay with normally open contact:
-
■ potential-free high-current relay:
-
PWM outputs:
4
■ convertible to 0-10 V:
4
Real-time clock:
check
Data interface:
RESOL VBus®, SD card slot, 10 / 100 Base TX Ethernet, Auto MDIX, WLAN
Energy-efficient SMPS:
check
Power supply:
100 ... 240 V~
■ with flowmeter:
check
■ with V40 flowmeter:
check
■ with Grundfos Direct Sensors™:
VFS/VFD
Antifreeze function for solar circuit:
check
Collector minimum limitation:
check
Collector emergency shutdown:
check
Store maximum limitation:
check
Store set temperature:
check
Store emergency shutdown:
check
Drainback option:
check
Tube collector function:
check
■ with adjustable time frame, interval:
check
Additional ΔT control:
check
Thermostat function:
check
Target temperature:
check
Heat dump function:
check
Heat exchange:
check
Store loading in layers:
check
Priority loading:
check
■ Parallel loading:
check
■ Store sequence control:
check
■ Progressive loading:
check
■ Successive loading:
check
■ Spreaded loading:
check
Solar circuit bypass:
check
Irradiation-dependent bypass:
check
Irradiation switch:
check
Afterheating suppression:
check
Parallel relay:
solar, free selectable
Twin pump for solar circuit:
check
Cooling functions and cooling mode:
check
Flow rate monitoring:
check
Pressure monitoring:
check
Function control:
check
Error relay:
check
DHW hygiene functions:
check
■ DVGW legionella protection:
-
■ Thermal disinfection:
check
DHW heating:
check
Heating circuit return preheating:
check
Boiler loading/Zone loading:
check
Solid fuel boiler:
check
Mixer control weather-compensated:
check
Mixer control with target temperature:
check
Circulation:
check
Function block:
check
Heating circuit antifreeze function:
check
Chimney sweeper function for the heating circuit:
check
Room thermostats:
check

1 system-dependent
2 via EM Extension Module(s) in total
Inputs: 15 Pt1000, Pt500 or KTY temperature sensor inputs (can optionally be used for remote controls, operating mode switches or potentialfree switches), 4 impulse inputs for V40 flowmeters, 2 frequency inputs, 1 CS10 solar cell, 2 analogue inputs for VFS/RPS Grundfos Direct Sensors™ or FRH humidity sensors, 2 digital inputs for VFD/RPD Grundfos Direct Sensors™ or FRHd humidity sensors
Outputs: 15 relays, 13 of them semiconductor relays for pump speed control, 1 potential-free relay, 1 potential-free extra-low voltage relay and 4 PWM outputs (convertible to 0-10 V signal outputs)
PWM frequency: 512 Hz
PWM voltage: 10.5 V
Switching capacity:
1 (1) A 240 V~ (semiconductor relay)
4 (2) A 24 V ⎓ / 240 V~ (potential-free relay)
1 (1) A 30 V ⎓ (potential-free relay)
Total switching capacity: 6.3 A 240 V~
Power supply: 100 – 240 V~ (50 – 60 Hz)
Supply connection: X
Standby: 0.82 W
Temperature controls class: VIII
Energy efficiency contribution: 5 %
Mode of operation: type 1.B.C.Y action
Rated impulse voltage: 2,5 kV
Data interface: RESOL VBus®, SD card slot, 10 / 100 Base TX Ethernet, Auto MDIX, WLAN 2.4~2.4835 GHz, Modbus RTU (optional)
Communication protocols: Modbus/RTU, Modbus/TCP and BACnet/IP
VBus® current supply: 35 mA
Functions: integrated Web server for configuration and function control, 7 integrated calorimeters, control of weather-compensated heating circuits. Adjustable system parameters and add-on options (menu-driven), balance and diagnostics functions, function control according to VDI 2169
Housing: plastic, PC-ABS and PMMA
Mounting: wall mounting, mounting into patch panels is possible
Indication/Display: full graphic display
Operation: 7 buttons, via the Web interface on the mobile device
Ingress protection: IP 20 / DIN EN 60529
Protection class: I
Ambient temperature: 0 … 40 °C
Pollution degree: 2
Dimensions: 253 x 258 x 47 mm
Radiated power: < 100 mW
Maximum altitude: 2000 m above MSL
Fuse: T6.3A
WLAN encryption: WPA / PSK, WPA2 / PSK
Relative humidity: 10 … 90 %
incl. 6 Pt1000 sensors (2 x FKP6, 4 x FRP6)

DeltaSol® MX Plus – Full kit

incl. 6 Pt1000 sensors (2 x FKP6, 4 x FRP6)
Article no.: 115 993 13 |  Price bracket A |  Price on request
  Add to wish list

Accessories

EM extension module

EM extension module

Sensor and relay extension module with 5 outputs and 6 inputs

RTA12 Remote control

RTA12 Remote control

Remote control for connection to the HKM3 and DeltaSol® MX, BX Plus, DeltaTherm® HC/HC MAX or EM Extension Module

RCP12 Room control unit

RCP12 Room control unit

Room control unit for connection to the DeltaSol® MX (from version 2.0) or DeltaTherm® HC (from version 1.09) and DeltaTherm® HC MAX

FRH/FRHd Humidity sensor

FRH/FRHd Humidity sensor

FRH Humidity sensor (analogue) » incl. JST connection cable

RTS room control unit

RTS room control unit

Room control unit


ROSA

Catalogues

Catalogue

  Product portfolio (PDF)