V40 Flowmeter

The RESOL V40 is a measuring instrument with a contactor for detecting the flow of water or water-glycol-mixtures and is used with the RESOL calorimeter. It is ready for use in the RESOL calorimeters. After a specific volume has passed, the V40 reed switch sends an impulse to the calorimeter. The heat quantity used is calculated by these impulses, the temperature difference and pre-defined parameters (glycol type, concentration, heat capacity etc.). Delivery includes connecting screw.
V40-15
Art. no. 280 016 80|Price on request
Overview table V40
TypeV40-15V40-25V40-35V40-60V40-150
Product version  11222
Impulse ratel/Imp125252525
Nominal widthDN2020252550
Connecting thread at the counterG...BZoll111 ¼1 ¼2 3/8
Connecting thread at the screw jointR...Zoll¾¾112
Max. operating pressurePmaxbar1616161616
Max. operating temperatureTmax°C120120130130130
Nominal flow rateQnm3/h1,52,53,5615
Max. flow rateQmaxm3/h3571230
Insulation limitQtl/h1202002804801200
Min. flow rate horizontalQminl/h305070120300
Min. flow rate verticalQminl/h60100---
Price bracket  BBBBB
Article no.  280 016 80280 011 20280 013 60280 013 70280 013 90
Price on request  

Note:
Version 1 is suitable for horizontal as well as for vertical mounting.
Version 2 is for horizontal mounting only.